Buat script 3G co umpt
- Buka file macro Conversion Plan Data File SRAN8.0
- Isi 3Gsite name dan Co-UMPT site name, save
- buka M2000 server 10.2.160.123
CME (X) à
Current Area
CME(X) à
Current Area à
Synchronize NE
Pilih site nya, pindahkan ke kanan
Buka CME Offline
Import file hasil convert dari CME online.
Pilih folder sampai ke cfgdata
2 Delete UTRP board(find
from “Root-Equipm-BBU information-Transmission Processing Unit of the extension
transmission board ”):
3 Modify SCTP link
slot No. from 4 to 7:
4 Open ETHPORT,
change subboard type in “ethport” to “Base board”.
-
Ubah ‘speed’ di port ‘1’ jadi 1000M dan
‘Fullduplex’
5 Change 5. 5.
DEVIP to slot 7(delete first, add again, optical port is port1, electrical port
is port0), delete the previously GTMU internal communication IP.
6 Modify IPPATH to
slot 7,subboard
type change to “Base Board”:change to port 1
7 Modify IPRT, change
to slot 7,subboard type to Base
Board. Add IPRT to GTMU by backplane tunnel.(Route type is “Exit Interface”,port type is
“Tunnel”)destination IP yang buat ke GTMU,
bisa gak kita pake IP yang dari devip port 1
8 Add
tunnel:Tunnel type “DL”
9 Change IPCLKLNK to
slot 7:
10. Check DHCP Server IP (IP BSC), pastikan ada IP nya
11. Check DHCP Relay, pastikan ENABLE
12. Export the NE file
10 Huawei engineer send this XML file to subcon.
---à Seharusnya
Kenyataannya
kita yg inject di LAB.